{"id":446,"date":"2024-01-10T17:44:36","date_gmt":"2024-01-10T15:44:36","guid":{"rendered":"https:\/\/thermalpro.lt\/?page_id=446"},"modified":"2024-02-13T09:19:03","modified_gmt":"2024-02-13T07:19:03","slug":"funke-silumokaiciai-ir-ju-dalys","status":"publish","type":"page","link":"https:\/\/thermalpro.lt\/en\/funke-heat-exchangers-and-their-parts\/","title":{"rendered":"\"Funke\" heat exchangers and their parts"},"content":{"rendered":"<div id=\"pageheader\"  data-column-margin=\"default\" data-midnight=\"dark\" data-top-percent=\"7%\" data-nectar-animated-gradient-settings=\"{&quot;color_1&quot;:&quot;#233caf&quot;,&quot;color_2&quot;:&quot;&quot;,&quot;speed&quot;:&quot;250&quot;,&quot;blending_mode&quot;:&quot;linear&quot;}\"  class=\"wpb_row vc_row-fluid vc_row full-width-section  zindex-set top_padding_phone_12pct right_padding_phone_15px left_padding_phone_15px bottom_margin_phone_0px\"  style=\"padding-top: calc(100vw * 0.07); padding-bottom: 0px;  z-index: 100;\"><div class=\"row-bg-wrap has-animated-gradient\" data-bg-animation=\"none\" data-bg-animation-delay=\"\" data-bg-overlay=\"false\"><div class=\"inner-wrap row-bg-layer using-image\" ><div class=\"row-bg viewport-desktop using-image using-bg-color\"  style=\"background-image: url(https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/header-funke.jpg); background-position: right center; background-repeat: no-repeat; background-color: #efe9e9; \"><\/div><\/div><\/div><div class=\"row_col_wrap_12 col span_12 dark left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col bottom_padding_desktop_0px bottom_padding_phone_0px\"  data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div id=\"fws_6ae9a9fdacbea\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row  bottom_padding_phone_0px\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div style=\" color: #ffffff;\" class=\"vc_col-sm-12 wpb_column column_container vc_column_container col child_column centered-text no-extra-padding inherit_tablet inherit_phone\" data-cfc=\"true\"  data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"nectar-split-heading  font_size_3vw font_line_height_1-5\" data-align=\"center\" data-m-align=\"inherit\" data-text-effect=\"default\" data-animation-type=\"twist-in\" data-animation-delay=\"0\" data-animation-offset=\"\" data-m-rm-animation=\"\" data-stagger=\"\" data-custom-font-size=\"true\" style=\"font-size: 3vw; line-height: 3.3vw;\"><h1 style=\"max-width: 900px; color: #ffffff;\">\"Funke\" heat exchangers and their parts<\/h1><\/div><div class=\"divider-wrap height_phone_0px\" data-alignment=\"default\"><div style=\"height: 20px;\" class=\"divider\"><\/div><\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdad4b5\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div style=\"margin-bottom: 0%; \" class=\"vc_col-sm-12 wpb_column column_container vc_column_container col child_column centered-text has-animation padding-6-percent inherit_tablet inherit_phone\"  data-using-bg=\"true\" data-padding-pos=\"left-right\" data-has-bg-color=\"true\" data-bg-color=\"#ffffff\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" ><div class=\"column-bg-overlay-wrap column-bg-layer\" data-bg-animation=\"none\"><div class=\"column-bg-overlay\" style=\"opacity: 1; background-color: #ffffff;\"><\/div><\/div>\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"divider-wrap height_phone_30px\" data-alignment=\"default\"><div style=\"height: 60px;\" class=\"divider\"><\/div><\/div><div class=\"img-with-aniamtion-wrap center\" data-max-width=\"50%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"100\" width=\"100\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/funke.svg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><div class=\"divider-wrap height_phone_30px\" data-alignment=\"default\"><div style=\"height: 15px;\" class=\"divider\"><\/div><\/div><div class=\"nectar-split-heading  font_line_height_24px\" data-align=\"center\" data-m-align=\"inherit\" data-text-effect=\"none\" data-animation-type=\"line-reveal-by-space\" data-animation-delay=\"0\" data-animation-offset=\"\" data-m-rm-animation=\"\" data-stagger=\"\" data-custom-font-size=\"false\" ><p style=\"max-width: 900px;\">Whether it is shell heat exchangers, plate heat exchangers, air-cooled heat exchangers or electric oil heaters, FUNKE offers thermodynamic solutions for practical application in all industrial sectors. In addition to heat exchangers of modular construction, we also manufacture according to customer specifications based on international standards and regulations.<\/p><\/div><div class=\"divider-wrap\" data-alignment=\"default\"><div style=\"height: 30px;\" class=\"divider\"><\/div><\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t\t<\/div> \n\t\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t<div id=\"fws_6ae9a9fdae61a\"  data-column-margin=\"default\" data-midnight=\"dark\" data-top-percent=\"1%\" data-bottom-percent=\"6%\"  class=\"wpb_row vc_row-fluid vc_row full-width-section\"  style=\"padding-top: calc(100vw * 0.01); padding-bottom: calc(100vw * 0.06); \"><div class=\"row-bg-wrap\" data-bg-animation=\"none\" data-bg-animation-delay=\"\" data-bg-overlay=\"false\"><div class=\"inner-wrap row-bg-layer\" ><div class=\"row-bg viewport-desktop using-bg-color\"  style=\"background-color: #ffffff; \"><\/div><\/div><\/div><div class=\"row_col_wrap_12 col span_12 dark left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col no-extra-padding inherit_tablet inherit_phone\"  data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"nectar-scrolling-tabs font_size_17px sub_desc_font_size_13px   tabselector\" data-m-display=\"visible\" data-nav-tag=\"h3\" data-tab-spacing=\"35%\" data-navigation-width=\"regular\" data-color-scheme=\"accent-color\"><div class=\"scrolling-tab-nav\"><div class=\"line\"><\/div><ul class=\"wpb_tabs_nav ui-tabs-nav\" data-spacing=\"30px\"><li class=\"menu-item active-tab\"><div class=\"menu-content\"><h3 class=\"tab-nav-heading nectar-bg-pseudo-accent-color\"><a class=\"skip-hash\" href=\"#tab_6ae9a9fdaf171\"><span>Plate heat exchangers<\/span><\/a><\/h3><a class=\"sub-desc skip-hash\" href=\"#tab_6ae9a9fdaf171\">High heat transfer efficiency in compact dimensions.<\/a><\/div><\/li><li class=\"menu-item\"><div class=\"menu-content\"><h3 class=\"tab-nav-heading nectar-bg-pseudo-accent-color\"><a class=\"skip-hash\" href=\"#tab_6ae9a9fdaf1a9\"><span>Shell-tube heat exchangers<\/span><\/a><\/h3><a class=\"sub-desc skip-hash\" href=\"#tab_6ae9a9fdaf1a9\">Quality and safety - for serial models or individual solutions.<\/a><\/div><\/li><li class=\"menu-item\"><div class=\"menu-content\"><h3 class=\"tab-nav-heading nectar-bg-pseudo-accent-color\"><a class=\"skip-hash\" href=\"#tab_6ae9a9fdaf1ba\"><span>Air-cooled heat exchangers<\/span><\/a><\/h3><a class=\"sub-desc skip-hash\" href=\"#tab_6ae9a9fdaf1ba\">Heat exchangers for cooling oil, fire-resistant liquids or emulsions with the help of ambient air in mechanical engineering, system engineering and special purpose automotive industry.<\/a><\/div><\/li><li class=\"menu-item\"><div class=\"menu-content\"><h3 class=\"tab-nav-heading nectar-bg-pseudo-accent-color\"><a class=\"skip-hash\" href=\"#tab_6ae9a9fdaf1c8\"><span>Electric oil pre-heaters<\/span><\/a><\/h3><a class=\"sub-desc skip-hash\" href=\"#tab_6ae9a9fdaf1c8\">Optimize your machine performance by using electrical energy to pre-heat oil, fire-resistant fluids and emulsions, especially in outdoor machines and systems.<\/a><\/div><\/li><\/ul><\/div><div class=\"scrolling-tab-content\">\n\t\t\t<div id=\"tab-ploksteliniai-silumokaiciai\" data-tab-icon=\"\" class=\"wpb_tab ui-tabs-panel wpb_ui-tabs-hide clearfix\">\n\t\t\t\t<div id=\"fws_6ae9a9fdaf8bb\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row  right_padding_0px left_padding_0px top_padding_tablet_30pct bottom_padding_tablet_25pct right_padding_phone_0px left_padding_phone_0px\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col child_column no-extra-padding force-phone-text-align-center inherit_tablet inherit_phone\"   data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"483\" width=\"1128\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/plattenwaermetauscher.jpg\" alt=\"Funke heat exchangers\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/plattenwaermetauscher.jpg 1128w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/plattenwaermetauscher-300x128.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/plattenwaermetauscher-1024x438.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/plattenwaermetauscher-768x329.jpg 768w\" sizes=\"auto, (max-width: 1128px) 100vw, 1128px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704795794302\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p>For industrial processes, renewable energy, power plants or heating, ventilation and air conditioning systems, FUNKE offers thermodynamically optimized solutions with plate heat exchangers that can be applied practically anywhere.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"#vertical-tabs-p\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"800\" width=\"1200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte_4b59894df9.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte_4b59894df9.jpg 1200w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte_4b59894df9-300x200.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte_4b59894df9-1024x683.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte_4b59894df9-768x512.jpg 768w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte_4b59894df9-900x600.jpg 900w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<h4>Gasketed plate heat exchangers<\/h4>\n<p>Gasketed plate heat exchangers consist of thin corrugated plates, which are sealed using rubber gaskets and pressed into the frame with screws. It can be removed for cleaning and maintenance. In addition, more wafers can be added later to achieve higher productivity.<\/p>\n<p>In order to cover the widest possible power range, several sizes are available with different number of plates and different designs. Heat exchangers can work with highly contaminated or highly viscous fluids, as well as when the temperature difference between hot and cold media is minimal. Depending on the application, special plates made of higher quality materials such as titanium plates for seawater applications are available.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p><strong>Advantages of gasketed plate heat exchangers<\/strong><\/p>\n<ul>\n<li>High thermal capacity due to OptiFlow, Bypass Stop and Best Wave systems.<\/li>\n<li>Lower investment costs due to compact design.<\/li>\n<li>Convenient service and maintenance thanks to high efficiency self-cleaning due to turbulent flow, visual identification of gaskets and the use of clip-on gaskets.<\/li>\n<\/ul>\n\t<\/div>\n<\/div>\n\n\n\n\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p><strong>FP SERIES<\/strong><\/p>\n<p><strong>Gasketed plate heat exchangers<\/strong><\/p>\n<p><strong>Technical data<\/strong><\/p>\n<ul>\n<li>Nominal connection values: DN 25 - DN 500 for volume flows of 0.5 m\u00b3\/h - 4,500 m\u00b3\/h<\/li>\n<li>Heat exchange surface\/plate: 0.04\u20133 m\u00b2<\/li>\n<li>Max. number of plates: 125\u2013800<\/li>\n<li>Max. operating pressure: 25 bar<\/li>\n<li>Max. operating temperature: 200\u00b0C<\/li>\n<\/ul>\n<p><strong>Safety<\/strong><\/p>\n<p>Double sealing in the inlet and outlet areas to prevent media mixing.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p><strong>FPDW SERIES<\/strong><\/p>\n<p><strong>Gasketed safety plate heat exchangers<\/strong><\/p>\n<p><strong>Technical data<\/strong><\/p>\n<ul>\n<li>Nominal connection values: DN 25 - DN 200 for volume flows of 0.5 m\u00b3\/h - 700 m\u00b3\/h<\/li>\n<li>Heat exchange surface\/plate: 0.04\u20131 m\u00b2<\/li>\n<li>Max. number of plates: 150\u2013700<\/li>\n<li>Max. operating pressure: 25 bar<\/li>\n<li>Max. operating temperature: 200\u00b0C<\/li>\n<\/ul>\n<p><strong>Safety<\/strong><\/p>\n<p>Designed with double plates with a special sealing system.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"slight-fade-in-from-bottom\" data-delay=\"100\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"800\" width=\"1200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte.jpg 1200w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte-300x200.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte-1024x683.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte-768x512.jpg 768w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_platte-900x600.jpg 900w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<h4>Brazed plate heat exchangers<\/h4>\n<p>Brazed plate heat exchangers are made from stamped stainless steel plates which are vacuum brazed to form a pressure resistant block of copper or nickel depending on the applicable requirements. Such heat exchangers can be used at high pressure and high temperature, but their design remains compact.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p><strong>Advantages of brazed plate heat exchangers<\/strong><\/p>\n<ul>\n<li>High thermal capacity: diagonal media routing and turbulators in the flow gaps.<\/li>\n<li>Highly resilient thanks to seam brazing rather than spot brazing<\/li>\n<li>Compact design also suitable for high-viscosity media because of high heat transfer<\/li>\n<li>Direct connection to the power unit without any additional holders thanks to elongated end plate<\/li>\n<\/ul>\n\t<\/div>\n<\/div>\n\n\n\n\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p><strong><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-401 alignright\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/tpl-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/tpl-300x200.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/tpl-1024x683.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/tpl-768x512.jpg 768w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/tpl-900x600.jpg 900w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/tpl.jpg 1200w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>TPL SERIES<\/strong><\/p>\n<p><strong>Areas of application<\/strong><\/p>\n<p>Primarily in the fields of hydraulics, compressed air, engine cooling and heat recovery. Universal use with various media. Extremely high heat transfer capacity due to the diagonal direction of the medium and special turbulator devices in the flow gaps. For higher viscosity material, the high heat transfer allows for the use of smaller units, which in turn take up less space.<\/p>\n<p><strong>Technical data<\/strong><\/p>\n<p>Heat exchange surface\/plate: 0.035\u20130.286 m\u00b2<br \/>\nMax. operating pressure: 36 bar<br \/>\nMax. operating temperatures: +200\u00b0C<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n<div class=\"wpb_text_column wpb_content_element\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-402 alignright\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/gplk-300x200.jpg\" alt=\"\" width=\"300\" height=\"200\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/gplk-300x200.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/gplk-1024x683.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/gplk-768x512.jpg 768w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/gplk-900x600.jpg 900w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/gplk.jpg 1200w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>GPL \/ GPLK \/ NPL \/ NPLK series<\/span><\/strong><\/p>\n<p><strong>Areas of application<\/strong><\/p>\n<p>Mainly used for heating, air conditioning, ventilation, engine cooling and recuperation. Universal use with various media.<\/p>\n<p><strong>Technical data<\/strong><\/p>\n<ul>\n<li>Max. operating pressure: 16\u201330 bar<\/li>\n<li>Max. operating temperatures: +200\u00b0C<\/li>\n<li>GPL \/ GPLK: plates brazed with copper<\/li>\n<li>NPL \/ NPLK: plates brazed with nickel<\/li>\n<\/ul>\n<p>Available as a safety heat exchanger with double walls.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t\t<\/div> \n\t\t\t<div id=\"tab-korpusiniai-vamzdiniai-silumokaiciai\" data-tab-icon=\"\" class=\"wpb_tab ui-tabs-panel wpb_ui-tabs-hide clearfix\">\n\t\t\t\t<div id=\"fws_6ae9a9fdb1e10\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row  right_padding_0px left_padding_0px top_padding_tablet_30pct bottom_padding_tablet_25pct right_padding_phone_0px left_padding_phone_0px\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col child_column no-extra-padding force-phone-text-align-center inherit_tablet inherit_phone\"   data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"483\" width=\"1128\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/rbw.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/rbw.jpg 1128w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/rbw-300x128.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/rbw-1024x438.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/rbw-768x329.jpg 768w\" sizes=\"auto, (max-width: 1128px) 100vw, 1128px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704800153761\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p>In the segment of shell-and-tube heat exchangers, FUNKE has a proven range of serial models as well as customized individual solutions. The product range also includes safety heat exchangers, providing solutions for all thermodynamic mechanical and systems engineering requirements. Shell-and-tube heat exchangers are mainly used to cool or heat fluids such as grease, hydraulic oil or water based on saturated steam. Water, water\/glycol mixtures or seawater can be used as the cooling medium.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdb27fb\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_bcf_ccf_sscf_ea4c2dffa1.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_bcf_ccf_sscf_ea4c2dffa1.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_bcf_ccf_sscf_ea4c2dffa1-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704801005368\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p><strong>BCF, CCF, SSCF<\/strong><\/p>\n<ul>\n<li>Tube bundle fixed or removable<\/li>\n<li>Exchange areas from 0.11 m\u00b2 to 11.45 m\u00b2<\/li>\n<li>Internal pipe dimensions: 6.35 x 0.5 mm and 9.5 x 0.8 mm<\/li>\n<li>Variable baffle spacing<\/li>\n<li>Tube side 1-, 2- or 4-way<\/li>\n<li>Horizontal or upright design with angled or clamping feet or stand<\/li>\n<li>Design pressure, shell side: 16 bar<\/li>\n<li>Design pressure, tube side: 10 bar<\/li>\n<li>Design temperature BCF \/ CCF: -10 \/ 150 \u00b0C, - SSCF: -10 \/ 230 \u00b0C<\/li>\n<li>Type examination in acc. with PED 2014\/68\/EU Module B<\/li>\n<li>CE marking<\/li>\n<\/ul>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"200\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_tdw_71c2751c81.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_tdw_71c2751c81.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_tdw_71c2751c81-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704801360087\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">TDW<\/span><\/strong><\/p>\n<ul>\n<li>Removable U-tube bundle with finned tubes<\/li>\n<li>Spiral deflection principle for high specific heat transfer performance<\/li>\n<li>Exchange areas from 0.05 m\u00b2 to 1.5 m\u00b2<\/li>\n<li>Internal tube dimensions: 14 x 1 mm in acc. with DIN EN 12452<\/li>\n<li>Pipe side 4-way<\/li>\n<li>Also available as tank installation variant TDW T<\/li>\n<li>Design pressure, shell side: 16 bar<\/li>\n<li>Design pressure, tube side: 8 bar<\/li>\n<li>Design temperature: 100\u00b0C<\/li>\n<li>Type examination in acc. with PED 2014\/68\/EU Module B<\/li>\n<li>CE marking<\/li>\n<\/ul>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"300\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_univex_71a9ea08e8.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_univex_71a9ea08e8.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_univex_71a9ea08e8-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704801884818\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">UNIVEX<\/span><\/strong><\/p>\n<ul>\n<li>Removable tube bundle<\/li>\n<li>Exchange areas from 0.15 m\u00b2 to 5.79 m\u00b2<\/li>\n<li>Internal tube dimensions: 6 x 0.5 mm<\/li>\n<li>Pipe side 4-way<\/li>\n<li>Design pressure, shell side: 16 bar<\/li>\n<li>Design pressure, tube side: 10 bar<\/li>\n<li>Design temperature: -10 \/ 120\u00b0C<\/li>\n<li>Without type examination and without CE-marking<\/li>\n<\/ul>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdb40c8\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row  right_padding_0px left_padding_0px top_padding_tablet_30pct bottom_padding_tablet_25pct right_padding_phone_12pct left_padding_phone_12pct\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col child_column no-extra-padding force-phone-text-align-center inherit_tablet inherit_phone\"   data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704810324891\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<h4>Individual solutions<\/h4>\n<p>In addition to series models, FUNKE supplies individual solutions in the shell-and-tube heat exchanger segment. Project engineering creates an optimal thermodynamic solution based on operational data, building regulations and specifications. A technically and economically optimized solution is always found that fully meets both the customer's needs and the company's standards to ensure maximum system security and efficiency.<\/p>\n<p>We manufacture custom-made shell-and-tube heat exchangers with a diameter of up to 3000 mm and a maximum weight of up to 60 t. External and internal coatings can also be applied, such as seawater and acid resistant coatings inside pipes and pipe assemblies.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdb471c\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"205\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_cp_5feb91d46d.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_cp_5feb91d46d.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_cp_5feb91d46d-300x128.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704808965290\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">CP (TEMA TYPE W)<\/span><\/strong><\/p>\n<p><strong>Design features<\/strong><\/p>\n<ul>\n<li>Robust design, removable smooth tube or finned tube bundle facilitates inspection<\/li>\n<li>Safety sealing of the floating tube sheet thanks to two seals and intermediate ring with signal holes<\/li>\n<\/ul>\n<p><strong>Application<\/strong><\/p>\n<p>Universal use \u2013 for liquid heat transfer and gas cooling. Typical application: oil cooling in hydraulics, large engines. Can be used as intercooler and aftercooler for compressors etc.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"200\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_a_100_a7cd727e7f.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_a_100_a7cd727e7f.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_a_100_a7cd727e7f-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704805324607\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong>A-100 (TEMA TYPE W)<\/strong><\/p>\n<p><strong>Design features<\/strong><\/p>\n<ul>\n<li>1-way, removable smooth tube bundle with floating base<\/li>\n<li>Broad size graduation thanks to large number of standardized units<\/li>\n<\/ul>\n<p><strong>Application<\/strong><\/p>\n<p>Cooling and drying of process gas or compressed air. Used as an intercooler or aftercooler in the compressor industry. The gas passing through the pipes is perfect as a pipeline coolant in the pipeline network.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"300\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_univex_71a9ea08e8.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_univex_71a9ea08e8.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_univex_71a9ea08e8-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704805510062\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">C-100 (TEMA TYPE P)<\/span><\/strong><\/p>\n<p><strong>Design features<\/strong><\/p>\n<ul>\n<li>The removable tube bundle with ring seal enables greater length differences resulting from different heat expansion between shell and inner tubes<\/li>\n<li>The tube bundle can be removed without loosening the end cap of the floating base<\/li>\n<\/ul>\n<p><strong>Application<\/strong><\/p>\n<p>Heat exchanger suitable for heat treatment of various media, air or gas. Can be used as an intercooler or aftercooler.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdb5e70\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_200_a036ccd97c.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_200_a036ccd97c.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_200_a036ccd97c-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704808975409\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">C-200 (TEMA TYPE M)<\/span><\/strong><\/p>\n<p><strong>Design features<\/strong><\/p>\n<ul>\n<li>Non-removable tube bundle with or without compensator in the shell<\/li>\n<li>Very good heat transfer performance thanks to maximum exchange area in the shell<\/li>\n<\/ul>\n<p><strong>Application<\/strong><\/p>\n<p>Intended for cooling and heating of various media and various mechanical and system engineering processes.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"200\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_300_a1f0708746.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_300_a1f0708746.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_300_a1f0708746-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704808985747\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">C-300 (TEMA TYPE U)<\/span><\/strong><\/p>\n<p><strong>Design features<\/strong><\/p>\n<ul>\n<li>The removable U-tube bundle with ring seal enables greater length differences resulting from different heat expansion between shell and inner tubes<\/li>\n<\/ul>\n<p><strong>Application<\/strong><\/p>\n<p>Especially suitable for cooling and heating various media at higher pressures. Can be used as a steam generator and condenser, also in processes with large temperature differences.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"300\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_400_a2cd7fae1c.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_400_a2cd7fae1c.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_400_a2cd7fae1c-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704809215742\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">C-400 (TEMA TYPE T)<\/span><\/strong><\/p>\n<p><strong>Design features<\/strong><\/p>\n<ul>\n<li>Removable tube bundle with a deflection chamber fastened to the floating tube sheet<\/li>\n<li>Tube bundle can be removed without loosening the deflection chamber<\/li>\n<li>This version has a large bundle inlet zone<\/li>\n<\/ul>\n<p><strong>Application<\/strong><\/p>\n<p>Process cooler, intercooler or additional cooler for gas and air, steam condenser. The field of application is mainly in the chemical industry.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdb75e7\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_500_5e2bd3ac84.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_500_5e2bd3ac84.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_c_500_5e2bd3ac84-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704809473491\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">C-500 (TEMA TYPE S)<\/span><\/strong><\/p>\n<p><strong>Design features<\/strong><\/p>\n<ul>\n<li>Removable tube bundle with deflection chamber fastened on the inside with clamping ring design<\/li>\n<li>Designed for strong heat expansion differences between shell and inner tubes<\/li>\n<li>Largest exchange area with shell diameter equivalent to other types<\/li>\n<\/ul>\n<p><strong>Application<\/strong><\/p>\n<p>Meets the highest demands (e.g. large temperature fluctuations) in the chemical industry and oil refineries. In addition to thermal treatment of liquid media, the S-500 can be used for gas or air cooling, as well as a steam condenser.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"200\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_wra_200_e882507f2c.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_wra_200_e882507f2c.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_zeichnung_wra_200_e882507f2c-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704809678307\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">WRA (TEMA TYPE M)<\/span><\/strong><\/p>\n<p><strong>Design features<\/strong><\/p>\n<ul>\n<li>Designed as exhaust gas heat exchanger with heat shield at gas inlet of fixed tube bundle<\/li>\n<li>Inlet temperatures up to 600\u00b0 C<\/li>\n<li>Inspection cover facilitates cleaning of the flue gas side<\/li>\n<\/ul>\n<p><strong>Application<\/strong><\/p>\n<p>Heat recovery from the exhaust gases of internal combustion engines, e.g. gasoline, diesel and fuel oil engines.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-4 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"slight-fade-in-from-bottom\" data-delay=\"300\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"206\" width=\"480\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/safe.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/safe.jpg 480w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/safe-300x129.jpg 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704810767496\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong>Safe design shell-and-tube heat exchanger<\/strong><\/p>\n<p>In the chemical, pharmaceutical or food industry, shipping or energy - safe heat exchangers are used where technological processes have strict cleanliness requirements, where contamination of cooling or process water can pose a threat to the environment, or mixing media can cause machine or system failure. This is possible due to the two-pipe system, where in the event of a pipe failure, the medium is diverted to a safe area, and this area is monitored by a monitoring system. This means that leaks can be detected at an early stage and media mixing can be avoided.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t\t<\/div> \n\t\t\t<div id=\"tab-oru-ausinami-silumokaiciai\" data-tab-icon=\"\" class=\"wpb_tab ui-tabs-panel wpb_ui-tabs-hide clearfix\">\n\t\t\t\t<div id=\"fws_6ae9a9fdb908a\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row  right_padding_0px left_padding_0px top_padding_tablet_30pct bottom_padding_tablet_25pct right_padding_phone_0px left_padding_phone_0px\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col child_column no-extra-padding force-phone-text-align-center inherit_tablet inherit_phone\"   data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"482\" width=\"1130\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_oelluft_header_d1dfd1e6a4.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_oelluft_header_d1dfd1e6a4.jpg 1130w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_oelluft_header_d1dfd1e6a4-300x128.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_oelluft_header_d1dfd1e6a4-1024x437.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_oelluft_header_d1dfd1e6a4-768x328.jpg 768w\" sizes=\"auto, (max-width: 1130px) 100vw, 1130px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704812338693\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p>Air-cooled heat exchangers use ambient air as a coolant instead of liquids. The main element of an oil-to-air cooler is an aluminum cooler block made of bar or plate. The cooled medium is directed through the cooler block through one or more channels, depending on the flow rate, and is cooled by ambient air with the help of a fan. Air-cooled heat exchangers are commonly used as additional coolers in the peak load range and wherever water is not available or piping would be too expensive.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdb99fd\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704812629469\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">OKAN Series<\/span><\/strong><\/p>\n<p>FUNKE OKAN series oil-air coolers for use in mechanical and systems engineering, construction machinery and special purpose vehicle structures. Available in 20 sizes with up to 6.2 kW\/K cooling capacity and single or three-way designs, as required. The wide range of oil-air coolers is flexible enough to suit most applications.<\/p>\n<p>Various individual solutions are available. Accordingly, special designs for marine or offshore applications are available, as are versions for use in potentially explosive environments.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"200\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"800\" width=\"1200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_okan_2_6180009369.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_okan_2_6180009369.jpg 1200w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_okan_2_6180009369-300x200.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_okan_2_6180009369-1024x683.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_okan_2_6180009369-768x512.jpg 768w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_okan_2_6180009369-900x600.jpg 900w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdba71a\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704812852666\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong><span class=\"headline\">Design features<\/span><\/strong><\/p>\n<ul>\n<li>Max. cooling capacity: approx. 6.2 kW\/K<\/li>\n<li>Max. operating temperature: for oil 100\u00b0C, for emulsion 90\u00b0C<\/li>\n<li>Max. operating pressure, static: up to 26 bar<\/li>\n<li>Ambient temperatures: -20\u00b0C to +40\u00b0C<\/li>\n<li>Cooling grid areas: 0.05 to 1.44m\u00b2<\/li>\n<li>Fan drives: three-phase motor, DC motor, hydraulic motor<\/li>\n<li>1- and 3-way design<\/li>\n<\/ul>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"200\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704812953465\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p><strong>Equipment options<\/strong><\/p>\n<ul>\n<li>Complete system incl. temperature control and pump<\/li>\n<li>Explosion-proof design<\/li>\n<li>Seawater-resistant surface protection<\/li>\n<li>Air filter for cooling element<\/li>\n<\/ul>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t\t<\/div> \n\t\t\t<div id=\"tab-elektriniai-alyvos-sildytuvai\" data-tab-icon=\"\" class=\"wpb_tab ui-tabs-panel wpb_ui-tabs-hide clearfix\">\n\t\t\t\t<div id=\"fws_6ae9a9fdbb2b9\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row  right_padding_0px left_padding_0px top_padding_tablet_30pct bottom_padding_tablet_25pct right_padding_phone_0px left_padding_phone_0px\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col child_column no-extra-padding force-phone-text-align-center inherit_tablet inherit_phone\"   data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"483\" width=\"1128\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/electrict.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/electrict.jpg 1128w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/electrict-300x128.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/electrict-1024x438.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/electrict-768x329.jpg 768w\" sizes=\"auto, (max-width: 1128px) 100vw, 1128px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704815965521\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p>Optimize equipment performance by using electricity to heat oil, non-flammable liquids and emulsions, especially in outdoor equipment or systems. The viscosity of oils and refractory fluids increases significantly at lower temperatures. This can cause extremely high pressure losses in pipelines, filters and cooling systems. When systems are started cold, especially oil\/air cooling systems installed outdoors, high start-up pressures can cause severe damage to pumps, filters, heat exchangers or other components. However, if the oil in the tank has been heated to the set operating temperature by the preheater, starting the systems and machines is much easier.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdbbc9e\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704816332406\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong>How the FUNKE oil pre-heater works<\/strong><\/p>\n<p>In an electric oil pre-heater, the heated liquid flows through a bank of U-shaped curved heating rods. The distance between the diverting segments is chosen to ensure a sufficient flow rate even at the lowest permissible flow. The standard load of the thermal zone is approx. 2 W\/cm\u00b2. At minimum flow and an inlet oil temperature of 60\u00b0C, the surface temperature of the heating rod is only 110\u00b0C. Therefore, it is significantly lower than the boiling point of oil. A temperature limiter built into the electric oil heater switches off the system at a temperature of 80\u00b0C.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"200\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"800\" width=\"1200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_elekto-oelvorwaermer-aufbau_cc59867b7f.jpg\" alt=\"\" srcset=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_elekto-oelvorwaermer-aufbau_cc59867b7f.jpg 1200w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_elekto-oelvorwaermer-aufbau_cc59867b7f-300x200.jpg 300w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_elekto-oelvorwaermer-aufbau_cc59867b7f-1024x683.jpg 1024w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_elekto-oelvorwaermer-aufbau_cc59867b7f-768x512.jpg 768w, https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/csm_elekto-oelvorwaermer-aufbau_cc59867b7f-900x600.jpg 900w\" sizes=\"auto, (max-width: 1200px) 100vw, 1200px\" \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div>\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div><div id=\"fws_6ae9a9fdbc90d\" data-midnight=\"\" data-column-margin=\"default\" class=\"wpb_row vc_row-fluid vc_row inner_row\"  style=\"\"><div class=\"row-bg-wrap\"> <div class=\"row-bg\" ><\/div> <\/div><div class=\"row_col_wrap_12_inner col span_12  left\">\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704817103190\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\"><strong>Areas of application<\/strong><\/p>\n<p>Electric pre-heaters are used for oils of 2 liquid groups and for heating fire-resistant liquids and emulsions according to PED 97\/23\/EC. Oil heaters are mainly used in machines and systems that are used in the field and on test benches that require a set oil temperature. FUNKE offers a modular line of oil heaters in 11 sizes to meet typical mechanical and systems engineering requirements, with heating capacities from 3 to 100 kW. Special designs are also available, such as high temperature devices up to 200\u00b0C and reduced heating zone loads of up to 1 W\/cm\u00b2.<\/p>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n\n\t<div  class=\"vc_col-sm-6 wpb_column column_container vc_column_container col child_column has-animation no-extra-padding inherit_tablet inherit_phone\"   data-padding-pos=\"top-bottom\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"fade-in-from-bottom\" data-delay=\"200\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t\n<div class=\"wpb_text_column wpb_content_element  vc_custom_1704817416513\" >\n\t<div class=\"wpb_wrapper\">\n\t\t<p class=\"headline\" style=\"text-align: left;\"><strong>Technical data<\/strong><\/p>\n<ul>\n<li>Heating insert with curved heating rods (like U-tube bundle)<\/li>\n<li>Housing: steel version<\/li>\n<li>Equipped with temperature limiter as standard<\/li>\n<li>Heating capacity: 3\u2013100 kW<\/li>\n<li>Max. operating pressure: (6 kW \/ &gt;9 kW) 25 \/ 16 bar<\/li>\n<li>Max. end temperature: 80\u00b0C<\/li>\n<li>High-temperature design possible with max. 200\u00b0C end temperature<\/li>\n<\/ul>\n\t<\/div>\n<\/div>\n\n\n\n\n\t\t<\/div> \n\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t\t<\/div> <\/div><\/div>\n\t\t\t<\/div> \n\t\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t<div id=\"fws_6ae9a9fdbd9cf\"  data-column-margin=\"default\" data-midnight=\"dark\"  class=\"wpb_row vc_row-fluid vc_row full-width-section vc_row-o-equal-height vc_row-flex vc_row-o-content-middle  top_padding_phone_50px bottom_padding_phone_50px\"  style=\"padding-top: 70px; padding-bottom: 70px; \"><div class=\"row-bg-wrap\" data-bg-animation=\"none\" data-bg-animation-delay=\"\" data-bg-overlay=\"true\"><div class=\"inner-wrap row-bg-layer\" ><div class=\"row-bg viewport-desktop\"  style=\"\"><\/div><\/div><div class=\"row-bg-overlay row-bg-layer\" style=\"background: #d8d8d8; background: linear-gradient(to bottom,#d8d8d8 0%,#ffffff 100%);  opacity: 0.5; \"><\/div><\/div><div class=\"row_col_wrap_12 col span_12 dark center\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col no-extra-padding force-tablet-text-align-center force-phone-text-align-center inherit_tablet inherit_phone\"  data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"nectar-split-heading  font_size_22px font_size_tablet_18px font_line_height_38px\" data-align=\"center\" data-m-align=\"inherit\" data-text-effect=\"default\" data-animation-type=\"line-reveal-by-space\" data-animation-delay=\"0\" data-animation-offset=\"\" data-m-rm-animation=\"\" data-stagger=\"\" data-custom-font-size=\"true\" style=\"font-size: 22px; line-height: 33px;\"><p style=\"max-width: 800px;\">Are you thinking about a new project? We will find out your needs and offer the optimal solution that meets your expectations.<\/p><\/div><div class=\"divider-wrap height_phone_60px\" data-alignment=\"default\"><div style=\"height: 20px;\" class=\"divider\"><\/div><\/div><div class=\"nectar-cta  alignment_tablet_default alignment_phone_default display_tablet_inherit display_phone_inherit\" data-color=\"accent-color\" data-using-bg=\"true\" data-style=\"arrow-animation\" data-display=\"inline\" data-alignment=\"left\" data-text-color=\"custom\" ><h4 style=\"color: #ffffff;\"><span class=\"link_wrap\" style=\"padding-top: 20px; padding-right: 40px; padding-bottom: 20px; padding-left: 40px;\"><a  class=\"link_text\" role=\"button\" href=\"https:\/\/thermalpro.lt\/en\/contact\/\"><span class=\"text\">Get in touch<\/span><svg class=\"next-arrow\" aria-hidden=\"true\" width=\"20px\" height=\"25px\" viewbox=\"0 0 50 80\" xml:space=\"preserve\">\n  <polyline stroke=\"#ffffff\" stroke-width=\"9\" fill=\"none\" stroke-linecap=\"round\" stroke-linejoin=\"round\" points=\"0, 0 45, 40 0, 80\"\/>\n  <\/svg>  <span class=\"line\"  style=\"background-color: #ffffff;\"><\/span> <\/a><\/span><\/h4><\/div>\n\t\t\t<\/div> \n\t\t<\/div>\n\t<\/div> \n<\/div><\/div>\n\t\t<div id=\"trusted\"  data-column-margin=\"default\" data-midnight=\"dark\" data-top-percent=\"3%\" data-bottom-percent=\"2%\"  class=\"wpb_row vc_row-fluid vc_row full-width-content vc_row-o-equal-height vc_row-flex vc_row-o-content-top  zindex-set\"  style=\"padding-top: calc(100vw * 0.03); padding-bottom: calc(100vw * 0.02);  z-index: 2;\"><div class=\"row-bg-wrap\" data-bg-animation=\"none\" data-bg-animation-delay=\"\" data-bg-overlay=\"false\"><div class=\"inner-wrap row-bg-layer\" ><div class=\"row-bg viewport-desktop using-bg-color\"  style=\"background-color: #ffffff; \"><\/div><\/div><div class=\"row-bg-overlay row-bg-layer\" style=\"background:linear-gradient(0deg, rgb(255,255,255) 4%, rgba(255,255,255,0) 30%, rgba(255,255,255,0) 75%, rgb(255,255,255) 96%);\"><\/div><\/div><div class=\"row_col_wrap_12 col span_12 dark left\">\n\t<div  class=\"vc_col-sm-12 wpb_column column_container vc_column_container col centered-text no-extra-padding column_position_static el_spacing_0px inherit_tablet inherit_phone\"  data-padding-pos=\"all\" data-has-bg-color=\"false\" data-bg-color=\"\" data-bg-opacity=\"1\" data-animation=\"\" data-delay=\"0\" >\n\t\t<div class=\"vc_column-inner\" >\n\t\t\t<div class=\"wpb_wrapper\">\n\t\t\t\t<div class=\"nectar-flickity not-initialized nectar-carousel vertical-alignment-middle custom-column-padding-1vw ticker-rotate\" data-ticker-speed=\"medium\" data-centered-cells=\"true\" data-pause-on-hover=\"\" data-touch-icon-color=\"default\" data-control-color=\"default\" data-overflow=\"hidden\" data-r-bottom-total=\"\" data-drag-scale=\"\" data-wrap=\"wrap\" data-spacing=\"10px\" data-controls=\"none\" data-pagination-alignment=\"default\" data-adaptive-height=\"\" data-border-radius=\"none\" data-column-border=\"\" data-column-padding=\"custom\" data-format=\"default\" data-autoplay=\"true\" data-autoplay-dur=\"5000\" data-control-style=\"material_pagination\" data-desktop-columns=\"7\" data-small-desktop-columns=\"6\" data-tablet-columns=\"5\" data-phone-columns=\"4\" data-column-color=\"\"><div class=\"flickity-viewport\"> <div class=\"flickity-slider\"><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/1.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/2.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/3.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/4.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/6.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/7.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/8.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/9.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/10.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/11.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/12.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/13.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/14.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/15.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/16.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/17.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><div class=\"cell\"><div class=\"inner-wrap-outer\"><div class=\"inner-wrap\" ><div class=\"img-with-aniamtion-wrap\" data-max-width=\"100%\" data-max-width-mobile=\"default\" data-shadow=\"none\" data-animation=\"none\" >\n      <div class=\"inner\">\n        <div class=\"hover-wrap\"> \n          <div class=\"hover-wrap-inner\">\n            <img loading=\"lazy\" decoding=\"async\" class=\"img-with-animation skip-lazy\" data-delay=\"0\" height=\"69\" width=\"200\" data-animation=\"none\" src=\"https:\/\/thermalpro.lt\/wp-content\/uploads\/2024\/01\/5.jpg\" alt=\"\"  \/>\n          <\/div>\n        <\/div>\n      <\/div>\n    <\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n\t\t\t<\/div> \n\t\t<\/div>\n\t<\/div> \n<\/div><\/div>","protected":false},"excerpt":{"rendered":"\u201eFunke\u201c \u0161ilumokai\u010diai ir j\u0173 dalys Nesvarbu, ar tai korpusiniai \u0161ilumokai\u010diai, plok\u0161teliniai \u0161ilumokai\u010diai, oru au\u0161inami \u0161ilumokai\u010diai ar elektriniai alyvos \u0161ildytuvai, FUNKE si\u016blo termodinaminius sprendimus prakti\u0161kai pritaikomus visuose pramon\u0117s sektoriuose. Be modulin\u0117s...","protected":false},"author":1,"featured_media":395,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"categories":[13],"tags":[],"class_list":["post-446","page","type-page","status-publish","has-post-thumbnail","category-funke"],"_links":{"self":[{"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/pages\/446","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/comments?post=446"}],"version-history":[{"count":8,"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/pages\/446\/revisions"}],"predecessor-version":[{"id":1647,"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/pages\/446\/revisions\/1647"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/media\/395"}],"wp:attachment":[{"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/media?parent=446"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/categories?post=446"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/thermalpro.lt\/en\/wp-json\/wp\/v2\/tags?post=446"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}